Advanced Illumination - PS24-TL 24 Volt Power Supply
- Universal input switching supply
- 24v regulated current DC – runs on 110-220v AC
- Power indicator light
- Tinned leads; marked negative/positive with wire nuts for easy connection
General Specs
|
Input Power |
90 VAC to 264 VAC universal; AC input frequency ; 47 Hz to 60 Hz |
|---|---|
|
Output Power |
24v, 1.67A (40W) |
|
Over Voltage Protection |
150% Max, non-condensing |
|
Over Current Protection |
Fully Short Circuit Protected |
|
MTBF |
50,000 HRs at full load and 25°C |
|
Safety Compliance |
UL1950 [E127643]; CSA 22.2 234 [LR56927-121]; TUV EN60950 [S9452057]; MITI [91-544899], [91-54489] |
|
Operating Temperature |
0 to 40°C |
Mechanical Specs
Part Number Key

More Product Information
- Guaranteed performance to 43.5 GHz with Extended K™ ports
- High output power allows measurement of high attenuation devices
- Wide dynamic range enables measurement of very low reflection artifacts
- Excellent corrected directivity minimizes measurement uncertainty
- SmartCal™ auto calibration unit reduces calibration and setup time
- Time domain with time gating option grants easier and faster fault identification
- Modern LAN interface for remote control is faster than GPIB
- A common GUI and SCPI interface within the ShockLine family
- Bias tee option simplifies test setups where the DUT needs DC biasing
- Universal Fixture Extraction (UFX) software option provides advanced de-embedding tools for test fixture extraction
- E-Band VNA
- Extended frequency range covering E-band and major parts of V band
- Fully assembled test system eliminates setup errors and increases reliability
- Tethered modules connect directly to the DUT increasing measurement stability
Flexibility
- DC, AC and RF/microwave device characterization, 1/f, WLR, FA and design debug
- Full thermal range of -60°C to +300°C
- Compatible with TopHat or IceShield
- Usage of manual and motorized positioners, probe cards within EMI-shielded environment
- Upgrade path to meet your future needs
- Stable and repeatable measurements over a wide thermal range
High accuracy and repeatability
- Reliable and repeatable contact
- Moisture-free, light-tight and EMI-shielded test environment with MicroChamber® technology
- Advanced EMI-shielding with PureLine and AttoGuard technologies available
- Superior low-leakage and low-noise measurements
- Safe and accurate hands-off testing
- Minimizes settling times for efficient measurements over full thermal range
See "Specifications & Details" tab for more key features
- High dispersion for reflective surfaces and shorter working distances.
- Provides a wider and more intense illumination area than the AL126.
- IP65 compliant washdown option is available, as are a wide spectrum of wavelengths.
- Available with polarization and diffusion light conditioning.
- This expandable compact bar light is pre-engineered for custom lengths in 2″ increments up to 20″.
- The SL162 is characterized as a High Intensity Spot/Coaxial Light and is designed primarily to replace fiber optic light sources in coaxial lensing applications.
- Optional couplers are available for use with Dolan-Jenner, Fostec, and Moritex fiber bundles.
- The spot light is designed with sufficient thermal management to provide 33kLux at a working distance of 4” (100mm).
- A very wide range of wavelengths from UV to IR are available.
- The BX2 Series of edge-lit backlights provides a highly diffuse source of illumination, packed within a thin and thermally efficient housing.
- The BX2 allows for configuration with polarization or collimation. A backlight configured with collimation is best suited for applications requiring a higher degree of edge clarity when imaging object silhouettes.
- This second edition of our edge-lit backlight series is more than twice as bright as previous BX and CX models.
- As with most planar backlight designs, this product is useful for edge detection, part location & orientation identification, presence & absence, hole detection and object gauging.
The laboratory and research industry faces unique challenges including long-standing, legacy pain points and frequently evolving needs. These include paramount safety and regulatory requirements for lab workers and patients alike, the need for high containment and sterility, and the integration of cutting-edge technologies. Complex and sensitive facilities require specialized testing solutions to ensure compliance, safety, and reliability. Effective planning and laboratory design and construction are crucial to creating environments that support advanced research and manufacturing processes, especially in the pharmaceutical and medical device sectors.
- The Narrow Linear Diffuse Light series is ideal for precision scanning of highly reflective materials.
- The DL151 is available in a wide range of wavelengths and provides up to 28kLux at a 1” (25mm) standoff.
- The extruded aluminum enclosure can be expanded in 2″ (51mm) increments from 2″ to 70″ (1778mm).
- Ultra-High Data Rate and Storage Capacity: Up to 16 Gbit/s and up to 64 TB
- Advanced Data Capabilities: On-Board Data Analysis
- Extended Configuration Flexibility: User-Configuration Canister Concept
- Integrated Telemetry Outputs: IRIG 106 Chapter 7 Support
- Full Spectrum of Interfaces: 10GigE, Video, Fiber Channel, ARINC 429, PCM, MIL-STD-1553, H.265 Video, Analog…
- Cybersecurity: Data-At-Rest Capabilities (encryption key management), Removable Secure Operational Disk (for extraction of non-volatile memory from system)
- The Direct PC bus access data acquisition system provides the required sampling rate and resolution to meet IEC 61000-4-7 measurement requirements and supports high-speed data transfers.
- PC-based Harmonic and Flicker test software provides real-time full-color data display updates and continuous PASS/FAIL monitoring.
- Automatic calculation of the maximum permissible system impedance Zsys, using the Zref and measured Flicker parameters, as required per EN/IEC 61000-3-11.
- Intuitive operating software provides IEC test setup, data analysis, display, with test reports in and MS Word format.
- High resolution, no gap acquisition data storage to ensure that all data can be streamed to disk (in ASCII format if needed) for later review and replay of the actual test.
- Single Step and Fast playback mode of test results.
Advanced Illumination
Machine Vision Lighting Solutions