HAEFELY EMC - AXOS 8 - Compact 7kV Surge, Telecom, Ring Wave, 5kV EFT, Dips/Drops
- Multi Tester with 16AMP CDN
- EFT/Burst 5kV IEC 61000-4-4
- Surge, Combination Wave 7kV IEC 61000-4-5
- Surge Magnetic field IEC 61000-4-9 (MSURGE-A loop antenna required)
- Ring Wave, 7kV IEC 61000-4-12 & ANSI
- Telicomm Wave, 7kV IEC 61000-4-5 & ITU
- AC Dips/Drops IEC 61000-4-11 (DIP 116 dips transformer required)
- DC Dips/Drops IEC 61000-4-29 (2x DC supplies required)
AXOS8 - Compact Test System
The AXOS8 expandable test system integrates the best features of several stand-alone test systems into one economical solution.
It can be individually combined with a 7 kV Surge Combination Wave, a 7 kV Ring Wave, a 7 kV Telecom Wave*, a 5 kV EFT/Burst, or Dips & Interrupts, along with an integrated single-phase coupling / decoupling network. This allows quick and completely automated testing to the most common IEC, EN, ANSI, ITU, IEEE, and UL standards.
The AXOS8 can be operated via the front panel by a large color graphic interface or remotely from the PC. The easy-to-use menu and the availability of predefined test routines for different standards make testing easy and reliable,
even for less frequent users. Numerous additional functions, such as the external start/stop function, allow easy test system integration in customer-specific test environments.
All the test parameters can be varied in a range that is far above the requirements of the standards. Together with the ability to change test parameters during testing, AXOS8 is not only the ideal product for compliance and pre-compliance testing, but it is also useful for monitoring and debugging during the design phase.
A wide range of cost-efficient and user-friendly coupling / decoupling networks for power lines, symmetrical and asymmetrical data, and signal lines are available as options.
*For Axos8 with “TW 8” module
Features
- Easy to operate with manual and automated test modes, software-assisted test preparation, pre-defined test routines, and visually aided test setups
- Economic & Efficient
- Touch screen guarantees reduction of time and effort -Experience and know-how at a reasonable price
- Safe and reliable operation by using safety interlock, warning lamp, and emergency stop functions
- Voltage and current monitoring of surge impulses and power provide valuable feedback to the test engineer.
- Automatic generation of test reports, including test parameters, test setup, and test result
STANDARDS
- IEC/EN 61000-4-4 EFT / Burst Ed. 2&3
- IEC/EN 61000-4-5 Surge E. 2&3 (1.2/50μs... 8/20μs )
- IEC/EN 61000-4-5 Surge (10/700μs)
- IEC/EN 61000-4-9 Magnetic Field
- IEC/EN 61000-4-11 AC Dips and Interrupts
- IEC/EN 61000-4-12 Ring Wave
- IEC/EN 61000-4-29 DC Dips and Interrupts
- IEC/EN 61000-6-1 Generic Residential
- IEC/EN 61000-6-2 Generic Industrial
- IEC/EN 60335-1 Household
- IEC/EN 60601-1 Medical
- IEC/EN 60950
- EN 55024
- IEEE C62.41
- ITU K.20, K.21, K.44, K.45
APPLICATIONS
- Compliance & pre-compliance testing of electrical products
- CE marking
- Product development and debugging
- Compliance testing of telecom and wireless devices
- Overtesting
Available Versions - Buy what you need, and add capability when you need
|
Model |
AXOS8 Compact No. 2490800 |
AXOS8 Surge No. 2490810 |
AXOS8 Telecom Wave No. 2490850 |
AXOS8 EFT/Burst No. 2490830 |
AXOS8 Dips No. 2490840 |
AXOS8 Ring Wave No. 2490820 |
|---|---|---|---|---|---|---|
|
7kV Surge IEC 61000-4-5 1.2/50μs, 8/20μs |
X |
X |
||||
|
7kV Telicomm IEC 61000-4-5 10/700 μs |
X TW 8 |
X TW 8 |
||||
|
5kV EFT IEC 61000-4-4 5/50ns |
X |
X |
||||
|
Surge MagField IEC 61000-4-9 |
X MSURGE-A |
X MSURGE-A |
||||
|
AC Dips/Drops IEC 61000-4-11 |
X DIP 116 |
X DIP 116, Incl. |
||||
|
7kV Ring Wave IEC 61000-4-12 IEEE 62.41 |
X |
X |
||||
|
DC DIPS/Drops IEC 61000-4-29 |
X DC Supply |
X DC Supply |
Included accessories: Mains Cable, User Manual, Calibration certificate, [Telecom Wave Modul “TW 8” 10/700μs(w/2490850)], [Automatic dips single phase transformer. “DIP 116”(w/2490840)]
Any combination of tests can be added to the Axos system—for example, Surge + Ringwave, Surge + EFT, or Dips + EFT—but if you need to add three or more tests together, the Axos8 Compact No. 2490800 model is required.
|
General AXOS5 SPECIFICATIONS |
|||
|---|---|---|---|
|
Display |
7“ / 800x480 / 24 bit with touchscreen |
AC Synch Input |
BNC, 10 V – 264 V AC |
|
External trigger input |
5 V TTL |
Analog output |
0 – 10 V, for use with external options |
|
Trigger output |
5 V TTL |
Safety circuit |
stops the test when unlocked |
|
EUT failed input |
5 V TTL |
Warning lamp output |
2 x 24 V / 1 A DC |
|
External start/stop input |
5 V TTL, starts / stops predefined test sequence |
User test storage |
Unlimited |
|
AUX. interface |
D-sub 37p is for external CDN, external transformer, etc. |
Remote interface |
Ethernet, RJ45 |
|
USB |
for USB memory stick |
Dimensions |
19“ / 6U (45 x 27 x 50 cm) |
|
Internal CDN V |
264 V AC/DC |
Weight |
30 kg |
|
Internal CDN A |
16 A AC/DC Continuous (500 A inrush current) |
Control Power |
85 V - 264 V 50/60 Hz |
|
IEC / EN 61000-4-4 EDITION 2 & 3 EFT / Burst |
|||
|---|---|---|---|
|
Output voltage |
0.2 – 5.0 kV ±10% at coaxial output (SHV BNC) |
Spike frequency |
1 Hz – 1 MHz |
|
Polarity |
pos/neg/alternate |
Burst duration |
10 µs – 1 s |
|
Output impedance |
50 Ohm |
Burst period |
1 ms – 10 s |
|
Rise time |
5 ns ±30% |
Test time |
1 s– 1,000 minutes, infinite |
|
Impulse duration |
50 ns ±30% at 50 Ohm 50 ns –15 +100 ns at 1,000 Ohm |
Trigger |
automatic, manual, external trigger input |
|
Burst mode |
normal, continuous, real, random |
Integrated single-phase coupling / decoupling network |
264 V AC / 16 A up to 220 V DC / 10 A |
|
IEC / EN 61000-4-5 EDITION 2 & 3 Surge combination wave |
|||
|---|---|---|---|
|
Output voltage |
0.2 – 7.0 kV ±10% |
Output current |
0.1 – 3.5 kA ±10% |
|
Voltage rise time |
1.2 µs ±30% |
Current rise time |
8 µs ±20% |
|
Voltage duration |
50 µs ±20% |
Current duration |
20 µs ±20% |
|
Polarity |
positive/negative/alternate |
Integrated single-phase CDN |
264 V AC / 16 A up to 220 V DC / 10 A |
|
Output impedance |
2 Ohm |
Impulse trigger |
Automatic 2 s – 100 min manual external trigger input |
|
Phase sync |
0 – 359° with 1° steps or asynchronous mode |
||
|
Counter preselect |
1 – 1,000 / infinite |
Counter |
100,000 |
|
Peak voltage monitor |
BNC output: 1000:1 display: 3 digits |
Peak current monitor |
BNC output: 1 kA/V display: 3 digits |
|
IEC / EN 61000-4-5 Telecom Wave / ITU K.20, K.21, K.44, K.45 (external TW 8 module) |
|||
|---|---|---|---|
|
Output voltage |
0.2 - 7.0 kV ± 10% |
Source impedance/coupling |
15 Ohm x 1 - 40 Ohm x 440 Ohm gas arresters x 4 |
|
Front time OCV |
10 μs ± 30% |
Front time SCC |
5 μs ± 20% |
|
Decay time OCV |
700 μs ± 20% |
Decay time SCC |
320 μs ± 20% |
|
Polarity |
Pos., neg., alt. |
Weight |
10 kg |
|
Outputs |
4 mm banana socket |
Dimensions |
19'' / 4U, (45 x 18 x 49 cm) |
|
IEC / EN 61000-4-11 EDITION 2 & 3 AND IEC / EN 61000-4-29 DIPS & INTERRUPTS |
|||
|---|---|---|---|
|
Max. voltage |
264 V AC/DC |
Interrupt time |
0.5 period – 800 periods 100 µs – 1000 minutes |
|
Max. current |
16 A AC/DC Continuous 20 A for 5 s 23 A for 3 s 40 A for 3 s > 500 A inrush current |
Interval time |
1 period – 800 periods 1 ms – 1000 minutes |
|
Trigger |
Automatic, manual, external |
Test time |
1 s – 1000 minutes, infinite |
|
Interrupt Dip level |
0% 0% – 99% (ext. voltage source) |
Phase sync |
0 – 359° 16 / 40 / 50 / 60 Hz asynchronous mode |
|
RMS voltage monitor |
BNC output: 100:1 display: 3 digits |
RMS current monitor |
BNC output: 10 A/V display: 3 digits |
|
IEC / EN 61000-4-12 EDITION 2 AND ANSI / IEEE C62.41 Ring Wave |
|||
|---|---|---|---|
|
Max. voltage |
0.2 - 7.0 kV ± 10% |
Repetition rate |
Up to 30 pulses/min |
|
Frequency |
100 kHz |
Polarity |
Positive/negative/alternate |
|
Rise time OC |
5 μs |
Floating output |
Max. 460 V / AC |
|
Rise time SC |
1 μs |
Phase sync accuracy |
± 1° |
|
Impedance |
12 Ohm, 30 Ohm |
Damping rate |
0.4 < peak1/peak2 < 1.1 0.4 < peak3/peak2 < 1.1 0.4 < peak4/peak3 < 1.1 |
|
Peak voltage monitor |
BNC output: 1000:1 -Disp: 3 dig. |
Peak current monitor |
BNC output: 1kA / V Disp: 3 dig |
Options and Accessories
|
Coupling |
|||
|---|---|---|---|
|
Automatic combined 3-phase Coupling/Decoupling Network for Surge, Ring Wave, EFT/Burst, 32 A (480 V AC/DC) |
No. 2490430 |
![]() |
|
|
Automatic combined 3-phase Coupling/Decoupling Network for Surge, Ring Wave,EFT/Burst 63 A (690 V AC/DC) |
No. |
![]() |
|
|
FP-SURGE 100M2 |
Manual 3-phase CDN for Surge, 100 A (690 V AC / 110 V DC) |
No. 2490180 |
|
|
FP-EFT100M2 |
Manual 3-phase Coupling/Decoupling Network for EFT/Burst, 100 A (690 V AC / 110 V DC) |
No. 2495860 |
|
|
IP4B |
EFT/Burst Capacitive Coupling Clamp according to IEC/EN 61000-4-4 Ed. 3 |
No. 2491300 |
|
|
PCD 121 |
Surge Combination Wave 1.2/50 µs…8/20 µs Coupling Network for testing symmetrical data and control lines, max. 4 wires |
No. 2498010 |
|
|
PCD 126A |
Surge Combination Wave 1.2/50 µs…8/20 µs Coupling Network for testing asymmetrical data and control lines, max. 4 wires & Ring Wave 100 kHz Coupling Network for testing symmetrical and asymmetrical data and control lines, max. 4 wires |
No. 2498030 |
|
|
DEC 5 |
Decoupling Network for testing symmetrically operated lines with Surge, Ring Wave 100 kHz, and Telecom Wave 10/700 µs, max. 4 wires |
No. 2490141 |
|
|
DEC 6 |
Decoupling Network for testing symmetrically or asymmetrically operated lines with Surge, Ring Wave 100 kHz, and Telecom Wave 10/700 µs |
No. 2490151 |
|
|
DEC 7 |
Decoupling Network for testing asymmetrically operated lines with Surge, Ring Wave 100 kHz, max. 4 wires |
No. 2490161 |
|
|
PCD-1000-4 |
1Gbit High-Speed Data Line CDN for Surge up to 4kV |
No. 0782012 |
|
|
Verification/Calibration Accessories |
|||
|---|---|---|---|
|
EFT/Burst Verification Set |
EFT/Burst Verification Set for Verification of EFT/Burst Impulse according to IEC/EN 61000-4-4 Ed. 3 (set includes PAT 50A + PAT 1000) |
No. 2499951 |
![]() |
|
Verification Adapter AXOS |
Verification Adapter AXOS, Used with 2499951 |
No. 4700783 |
![]() |
|
Transducer Plate |
Transducer Plate for IP4B Capacitive Coupling Clamp Verification/Calibration according to IEC/EN 61000-4-4 Ed. 3 |
No. 0781820 |
|
|
PDP 8000 |
Differential High Voltage Probe 1000:1 Used for Surge/Ring Wave Voltage |
No. 2499911 |
|
|
CP 101 |
Current Probe Model 101 Used for shorted Surge/Ring Wave Current |
No. 2499931 |
|
|
Software |
|||
|---|---|---|---|
|
AXOS Remote Control |
Remote Control Option for AXOS 5 & AXOS 8 |
No. 2490440-S |
![]() |
|
AXOS Reporting Software |
Reporting Software for AXOS 5 & AXOS 8 |
No. 4700975 |
![]() |
|
Others |
|||
|---|---|---|---|
|
AXOS, TW 8 |
Telecom Wave 10/700 µs Impulse Module for Axos8 only |
No. 2490851 |
![]() |
|
DIP 116 |
Automatic Dips Transformer 16A for AC Voltage Dips according to IEC/EN 61000-4-11 |
No. 2490410 |
![]() |
|
MSURGE-A |
Pulsed Magnetic Field coil 1 x 1 m according to IEC/EN 61000-4-9 |
No. 2490441 |
|
|
Switch Box AXOS |
Switchbox for connecting more than two units to AXOS (e. g. FP-COMB 32 and TW 8) |
No. 4701044 |
|
|
ES-P12 |
External Emergency Stop Switch |
No. 4700751 |
|
|
WL-P12 |
External Warning Lamp |
No. 4700750 |
|
|
VTM 15000 |
Impulse Transformer for Insulation Testing 1.2/50 µs (a separate Surge generator will be needed) |
No. 2499960 |
|
|
VTM 15000/05 |
Impulse Transformer for Insulation Testing 1.2/50 µs low energy 0.5 Joule (a separate Surge generator will be needed) |
No. 2499692 |
|
|
Factory Calibration is included with the unit |
|||
|---|---|---|---|
|
AccCal AXOS 8 Compact |
Accredited Calibration to ISO / IEC 17025 of AXOS8 Surge, EFT, Ring wave, Dip/Drops |
No. 2490900 |
|
|
AccCal AXOS 8 Surge |
Accredited Calibration to ISO / IEC 17025 of AXOS8 Surge |
No. 2490905 |
|
|
AccCal - AXOS 8 EFT/Burst |
Accredited Calibration to ISO / IEC 17025 of AXOS8 EFT |
No. 2490910 |
|
|
AccCal - AXOS 8 Ring Wave |
Accredited Calibration to ISO / IEC 17025 of AXOS8 Ring Wave |
No. 2490915 |
|
|
AccCal - AXOS 8 Voltage Dips |
Accredited Calibration to ISO / IEC 17025 of AXOS5 Dip/Drops |
No. 2490920 |
|
|
AccCal - DIP 116 |
Accredited Calibration according to ISO / IEC 17025 of Dip 116 |
No. 2490421 |
|
|
AccCal - TW8 |
Accredited Calibration according to ISO / IEC 17025 of TW 8 Telicomm pulse |
No. 2490925 |
|
SOFTWARE
REPORTING SOFTWARE
The reporting software automatically creates a test report. The main header can be adjusted with the individual company logo or any other text required. The data input can be supplied directly via the remote control software or when saving the data on a USB drive. Furthermore, the data can be used directly from the sequence mode menu, and the report is generated. Detailed information will be provided with the reporting software tool itself. The reporting software is compatible with Windows 7 and Windows 10 (32- and 64-bit).
REMOTE CONTROL SOFTWARE
The optional remote control software simply enables the user to control the AXOS5 and AXOS8 remotely using a standard PC, Tablet, or Smartphone. The connection can either be established by inserting an ethernet cable “point to point” or via a Wi-Fi network (a separate access point will be required).