Maury MW - Manual Noise Generators - NC6000A-8000A Series
- Additive white Gaussian noise
- Integrated amplifier
- Manual attenuator
- NC6000A -BER testing, and SNR applications
- NC8000A – Secure signal jamming
- Military Applications
- Custom configurations available (consult factory)
The NC6000A and NC8000A Series instruments are designed for general-purpose noise applications on the bench, or in a rack test station. The manual controls make it simple to operate and reduce test set up time. Standard units can be modified for specific customer requirements. Please consult the factory for pricing and availability of these requests.
|
Output |
Attenuator Range |
Impedance |
Typical VSWR |
|---|---|---|---|
|
White Gaussian noise up to 26.5 GHz |
0 to 10 dB in 1 dB steps |
50 Ohms |
1.5:1 |
More Product Information
- Low noise
- Excellent line⁄load regulation
- Coarse and fine voltage controls
- Constant voltage or constant current operation with automatic crossover and mode indication
- Individual ON⁄Off switch per output (not including fixed output)
- Switchable 3.3V⁄5V output on triple output model
- Switchable remote sense (XPH 1810 and XPH 4210 models)
- AWGN as high as +13 dBm
- Bandwidths up to 18 GHz
- Bandwidth, output power, and flatness can be modified for specific applications
- TTL controlled attenuation
The NC1000 Series amplified noise modules produce AWGN as high as +13 dBm, and have bandwidths up to 18 GHz. The high power modules are designed to test noise immunity for Cable TV equipment, secure communication channels, and military jamming systems. The lower power modules, <= 0 dBm, are random jitter sources for many applications including, PCIexpress, Infiniband, and 10 GigE. The Bandwidth, output power, and flatness can be modified for specific applications. A newly developed TTL controlled attenuation feature is also available.
- Light-tight version and EMI-shielded version for low noise and light-sensitive measurements
- Application flexibility, ideal for use in high frequency applications
- Sized to accommodate thermal chucks, laser cutter, and video equipment on the probe system
- Suitable for integration with vibration isolating tables
- Reduced dark noise levels and improved dark offset
- Improved sensitivity, including NIR response
- In-camera image pre-processing (lens shading correction, pixel correction)
- Large full well when using in-sensor binning >142Ke
- Thousands of frames per second in Partial Scan Mode (ROI)
- Multi-ROI support (up to 32 ROI) and Cycling Mode
- Advanced Sequencer functions of different features
- Calibration-grade metrology standards
- Used for VNA calibration and/or calibration validation
Maury mismatch airlines have been designed as verification standards to be used in VNA calibration validation. Each mismatch airline is provided with factory S-parameters data that can be compared with user-measured S-parameters for VNA calibration validation. Measurement uncertainty is also provided, and uncertainty boundaries can be used for definitive calibration validation when used in conjunction with MT940B Insight Real-Time Uncertainty Add-On.
Not all amplifiers are created equal, so how can you be certain that an amplifier will work for your needs? You deserve to be confident that the amplifiers used with your test-and measurement lab benches will meet the requirements of your specific applications, are reliable, and are equally well-supported pre-and post-sale. When it comes to application expertise, reliability and support, there is no company that does it better than Maury.
- Vector Network Analyzer Frequency Range from 10 MHz up to 3.2 GHz
- Spectrum Analyzer Frequency Range from 9 kHz up to 3.2 GHz
- -156 dBm/Hz Displayed Average Noise Level (Typ.)
- -98 dBc/Hz @10 kHz Offset Phase Noise (1 GHz, Typ.)
- Total Amplitude Accuracy < 1.2 dB
- 1 Hz Minimum Resolution Bandwidth (RBW)
- All-Digital IF Technology
- Standard Preamplifier
- Distance to fault capability using VNA time domain analysis
- Up to 1.5 GHz Tracking Generator Kit
- Built-in Advanced Measurement capability (CHP, ACPR, OBW, CNR, TOI, etc)
- 10.1 lnch WVGA (1024 x 600) Display
Software for calibration automation. Available with CamOCR Camera Readout module. Caliber can run autonomous calibrations through remote control or provide guidance to operator in manual mode. Calculated results and uncertainties can be exported to WinQBase or third party software.
- Automatic calibration of instruments
- In line with ISO17025 and other metrology standards
- Automated optical readout module for multimeters
- Users are free to add any custom standard or DUT
- Output White Gaussian noise
- 127 dB of attenuation; 0.1 dB step size
- Units > 2 GHz have total attenuation of 79.9 dB
- Low distortion signal path
- Noise attenuator accuracy:
- ±0.2 dB or 0.5% at 1 – 500 MHz
- ±0.2 dB or 1% at 0.5 – 1.0 GHz
- ±0.3 dB or 2% at 1 – 2 GHz
- Standard connectors SMA female
- Power 115 VAC, 60 Hz; 110 VAC, 220 VAC
- Operating Temperature: -10° to +65°C
Maury Microwave
Maury Microwave is a pioneering leader in the design and manufacture of precision RF and Microwave calibration, test & measurement, and modeling solutions that are powering global efforts toward a more secure, more connected, future.
Maury Microwave offers Measurement and Modeling Device Characterization Systems and Services including nonlinear passive, active and hybrid-active fundamental and harmonic load pull, non-50Ω X-Parameter modeling, pulsed IV Pulsed s-parameters and compact transistor modeling, and patent-pending ultra-fast/accurate noise parameters.