NoiseKen - Electromagnetic Field Visualization System / EPS-02Ev3
- A real-time diagnostic tool supports EMC/EMI debugging.
- Fast visualize EMC/EMI problems.
- Enables easy comparison of countermeasures before and after.
- Capable of measurement from entire products to single components.
- Factor-editor function provides correction of antenna characteristics, cable loss and preamplifier.
- User friendly compact design.
- Customer supplied spectrum and probes acceptable (Please consult)
Three-Dimensional Indication (Time, Frequency, Amplitude) Simplifies EMC/EMI Debugging
EPS is a EMC/EMI debugging tool enabling designers to rapidly perform pre-measurement, failure point identification, and improvement efficiency confirmation in EMC/EMI countermeasure process of product design. How does it work?
The software detects locations of probes by color discrimination through camera’s image sensors*, real time analysis measured signal frequency, shows a heat map by overlapping electromagnetic field strength and real images of measured objects.
Simplifies EMC/EMI Debugging Three-Dimensional Indication (Time, Frequency, Amplitude)
Specifications
Parameter |
Specification / Function |
---|---|
Frequency Range |
100 kHz ~ 3 GHz *Depends on the electromagnetic field probe specifications (The above is for ETS probes) |
Measurement Unit |
dB μV、dBm |
Sensor / Probe |
φ 60 / 30 / 10 mm loop coil (magnetic field), φ 36 mm ball (electric field), φ 6 mm tip (electric field) Total 5 types *Depends on electromagnetic probe specifications (Probe by ETS-Lindgren) |
Probe Cable Length |
2m(N(P)-BNC(P) (Coaxial connector cable) |
Data Recording Method |
Single / Free Run /Max Hold / Max Peak Data* |
Auxiliary Function |
Save / load / export / comment input / factor re-read / camera image retake / up-down & right-left inversion of camera image / ghost display of camera image / Screen enlargement-reduction |
Compatible Operating System |
Windows 7 / 10 |
System Configuration |
Electromagnetic field probe (PN 7405) , BNC (P) -N (P) connector coaxial cable (02-00150A), Three Color Probe Head Cover (03-00111A), RF preamplifier (00-00019A), Spectrum analyzer, Control PC |
Accessories |
LAN cable, Camera, USB cable extension 2 m for camera, Tripod for camera, Software, USB protect key, Instruction manual |
*Peak Hold: Displays the trace data with the largest peak value from the trace data measured at each measurement point.
Electromagnetic Field Probe (PN 7405) Frequency Specialization
Model |
Type |
Electric Field / Magnetic Field |
Construction |
Recommended Frequency Range |
---|---|---|---|---|
901 |
6 cm Loop |
Magnetic Field |
Sealed Loop |
3 MHz ~ 500 MHz |
902 |
3 cm Loop |
Sealed Loop |
5 MHz ~ 1 GHz |
|
903 |
1 cm Loop |
Sealed Loop |
10 MHz ~ 3 GHz |
|
904 |
3.6 cm Ball |
Electric Field |
Spherical Dipole |
10 MHz ~ 3 GHz |
905 |
6 mm Stub Tip |
Spherical Dipole |
50 MHz ~ 3 GHz |