Sorensen - SFA Series 5kW to 30kW High Slew Rate Current Source

  • High Power Density DC Power Supply: Up to 15 kW in a 3U / 30 kW in a 6U chassis 
  • Wide Voltage Range: 0-40V up to 0-600V, in increments of 5 kW from 5 to 30 kW 
  • Fast Load Transient Response: Protection from undesired voltage excursions 
  • Low RMS and P-P Noise: Suitable for the most sensitive applications 
  • Parallelable DC output up to 150 kW: Expandable as your requirement grows. 
  • Modular Design: Upgradeable for the ultimate in investment protection 
  • Sequencing: Program custom waveforms 
  • Easy-to-read Fluorescent Display: SGI supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages. 
  • 16-bit Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control 
  • Ethernet Control: LXI Class C compliant communication through an integrated web server 
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only) 
  • Hardware Trigger: Ethernet Option Only 
  • 5-Year Warranty

Electrical Characteristics

Control Mode

Current Control

Front Panel Meter Accuracy

Voltage ±0.5% of full-scale + 1 digit 

Current ±0.5% of full-scale + 1 digit

Load Regulation

(no load to full load, nominal AC input) Current 0.1% of rated output current

Line Regulation

(±10% of nominal AC input) Current 0.05% of rated output current

Current Ripple

1% p-p of full-scale current

Transient Response

Output current recovers to within 1% of current setpoint within 1ms for a 10 to 100% or 100% to 10% step load change

Output Slew Rate (10-90% resistive load)

250A/ms (400A/ms typical) rise, 200A/ms typical fall; 160V model 87A/ms/5kW (145A/ms/5kW typical), 60A/ms, typical, fall

Output Capacitance

60V Models: <2µF 

160V Models: <3µF

Stability

±0.05% of setpoint after 8–hr. warm-up at fixed line, load, and temperature using remote sense

Power Factor

>0.9 typical for 208/220VAC input 

>0.78 typical for 380/400VAC input 

>0.7 typical for 440/480VAC input

Remote Analog Control

Current Setpoint Accuracy ±0.8% of full-scale output 

Overcurrent Protection ±1% of full-scale output 

Resistive Control 0–5 kW = 0-100% Current 

Voltage Control 0–5 or 0–10 VDC = 0-100% Current 

Overcurrent Protection 0–5.5 VDC = 0-110%

Efficiency

87% typical at full load, nominal line

Remote Control/Monitor

On/Off control via contact closure, 6-120 VDC or 12-240VAC, and TTL or CMOS switch, current monitor, OCP limit set, summary fault status

Overvoltage Protection

Fixed at approximately 110% of the rating compliance voltage. Reset requires cycling the front panel standby power switch off/on 

Isolated Analog Control (option) 

Input to Output Isolation: 500 V 

Compliant with maximum terminal float voltage. 

Recommended operation under SELV normal conditions.


Environmental Characteristics

Ambient Operating Temperature

0 to 50°C

Storage Temperature

-25 to 65°C

Temperature Coefficient

Current Setpoint 0.03% / °C of rated current

Cooling

Internal Fans. Zero clearance stacking

Humidity

0 to 90% at 40°C; 0 to 50% at 25°C non-condensing

Altitude

Full power at 5,000 feet, 10% derating of full power for every 1,000 feet above 5,000 feet

Regulatory

Certified to UL/CSA 61010 and IEC/EN 61010-1 CE Compliant (LVD and EMC Directives)


Input Power Options

Configuration

3–phase, 3–wire plus ground. Not phase rotation sensitive. Neutral not used

Voltage Selection

208/220 VAC±10%, 47 to 63 Hz 

380/400 VAC±10%, 47 to 63 Hz 

440/480 VAC±10%, 47 to 63 Hz


Physical

Up to 15kW in 3U

19.00in W x 25.12in D x 5.25inH; 80 lbs. 

(48.3cm W x 63.8cm D x 13.3cm H; 36 kg)

15 - 30kW in 6U

19.00in W x 25.12in Dx 10.5in x H; 160 lbs. 

(48.3cm W x 63.8cm D x 36.7cm H; 73 kg)

More Product Information

AMETEK Programmable Power

Programmable Precision AC & DC Sources, Loads and Custom Power Solutions

Sorensen - SFA Series 5kW to 30kW High Slew Rate Current Source
Sorensen - SFA Series 5kW to 30kW High Slew Rate Current Source