Teledyne LeCroy - Active Voltage Probes
The ZS Series probes provide high impedance and an extensive set of probe tips and ground accessories to handle a wide range of probing scenarios. The high 1 MΩ input resistance and low 0.9 pF input capacitance means this probe is ideal for all frequencies. The ZS Series probes provide full system bandwidth with all Teledyne LeCroy oscilloscopes with bandwidths of 4 GHz and lower.
Engineers must commonly probe high-frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. Active voltage probes feature both high input R and low input C to reduce circuit loading across the entire probe/oscilloscope bandwidth. With low circuit loading, and a form factor that allows probing in confined areas, the active voltage probe becomes the everyday probe for all different types of signals and connection points.
|
Model |
Bandwidth |
Input R |
Input C |
Dynamic Range |
OffsetRange |
Interface |
|---|---|---|---|---|---|---|
|
ZS1000 |
1 GHz |
1 MΩ |
0.9 pF |
± 8 V |
NA |
ProBus |
|
ZS1500 |
1.5 GHz |
1 MΩ |
0.9 pF |
± 8 V |
± 12 V |
ProBus |
|
ZS2500 |
2.5 GHz |
1 MΩ |
0.9 pF |
± 8 V |
± 12 V |
ProBus |
|
ZS4000 |
4 GHz |
1 MΩ |
0.6 pF |
± 8 V |
± 12 V |
ProBus |
More Product Information
- Repeatable high product quality due to automated production processes
- Optical output power up to 2500 mW
- Manually focusable
- Active cooling integrated
- TTL modulation up to 200 kHz
- Analog intensity control
- IP 67
- Certified according to the railway standard: DIN EN 61373:2011-04
- PC control via Graphical User Interface (GUI)
The ZQ1 HighPower is a performance-optimized laser module designed for demanding imaging and measurement applications. With up to 2.5 W optical output and available wavelengths of 760 nm, 808 nm, and 450 nm, it offers maximum flexibility for industrial sensing, analytics, and medical technology. The 762 nm diode in particular delivers a significantly improved signal-to-noise ratio, higher camera sensitivity, and reduced ambient light effects—making it ideal for outdoor measurements and daylight conditions. Typical applications range from 3D triangulation and infrastructure inspections (road and rail) to spectroscopy, precision metrology, and medical procedures. With its robust thermal design, active stabilization, and OEM options, the ZQ1 HighPower is built for reliable performance in both industrial and outdoor environments.
- Combine up to 6 SPDT and 6 multiport high-performance building blocks in a 2U footprint
- Extended life and self-terminating options provide maximum design flexibility
- Embedded web interface provides interactive utility to monitor and control relays from anywhere in the world
- Flexible API supports IVI and Linux development environments minimizing software investment
- LXI Trigger Event implementation provides seamless test synchronization with external devices
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
- Up to 4 GHz Bandwidth
- ±60 V Offset Capability
- ±800 mV Dynamic Range
- 50 kΩ DC Input Impedance
- 1.2x Attenuation for low additive noise
- MCX terminated cable with wide variety of connections:
- Solder-in (4 GHz)
- Coaxial Cable to U.FL receptacle (3 GHz)
- MCX PCB Mount (4 GHz)
- Browser (500 MHz)
- ProBus Interface
- Global shutter and rolling shutter CMOS sensors available
- USB3 Vision
- High sensitivity with both front and back illuminated sensors (BSI)
- Side mounted USB connectors for ease of use in OEM solutions
- High sensitivity with pixel sizes from 2 µm to 3.45 µm
- Windows operating system and Linux SDKs (for embedded vision systems)
- 3-Year Warranty
-
Monochrome (G-131B) and color (G-131C) models
-
GigE Vision interface with Power over Ethernet
-
Screw mount RJ45 Ethernet connector for secure operation in industrial environments
-
Supports cable lengths up to 100 meters (CAT-6 recommended)
-
Comprehensive I/O functionality for simplified system integration
-
Popular C-Mount lens mount
-
Easy camera mounting via standard M3 threads on top and bottom of housing or optional tripod adapter
-
Easy software integration with Allied Vision's Vimba Suite and compatibility to the most popular third party image-processing libraries.
-
Defect pixel masking feature with the Defect Mask Loader tool that allows you to manage a user defined defective pixel list to match your application and optimize the life cycle of the camera.
-
Select between B 270 ASG protection glass and filter types: Jenofilt 217 IR cut filter, Hoya C-5000 IR cut filter, RG715 IR pass filter, or RG830 IR pass filter
WaveMaster 8000HD is the only high speed oscilloscope designed for all stages of product development, whether first-silicon characterization, link validation over channels, or debugging across the entire the protocol stack. No other high speed oscilloscope supports more engineering tasks with more unique tools.
- Exceptional signal characterization performance
- Unrivaled validation and debug capabilities
- Comprehensive serial data expertise
- Up to 20 GHz bandwidth and 80 GS/s sample rate
- The most advanced oscilloscope user interface
- The industry’s only true hardware 14.1 Gb/s serial trigger
- Low Jitter Measurement Floor and exceptional timebase stability
- Comprehensive set of serial data analysis, debug, validation and compliance tools
- Integrated 50 Ω and 1 MΩ inputs for true connection and probing flexibility
- Integrated standard and custom measurements and math functions for unrivaled analysis capability
- Multi-lane serial data eye, jitter and crosstalk analysis
- Real-time de-embedding, emulation, and equalization
- Single-mode fiber with FC/PC connector
- Unique line uniformity and μ-optics for thin lines ( <15 μm [1/e²] )
- Red, green and blue wavelengths
- Optical output power up to 35 mW
- < 15 μm bei FWHM
- M2 < 1.05
- Analog and simultaneous TTL modulation up to 200 kHz
- Fail-safe for critical applications (e. g. medical)
- OEM-version without housing and TEC (PCB-version)
Teledyne LeCroy