VisioCablePro - Automatic Bobbin Unwinder ABU24
- Enables up to 24 braiding spools to be unwound at the same time
- Appropriate spools:
- Diameter of mandrel 23 mm (standard version)
- Spool outer diameter up to 100 mm
- Other spools with different inner and outer diameters possible
- Suitable for different winding materials, e.g. metal wire, plastic, natural, glass and carbon fibres
|
Technical Details |
|
|---|---|
|
Size (W x L x H) |
1200 x 800 x 700 mm 47.24 x 31.5 x 27.55 Inch |
|
Weight |
47 kg | 104 lbs 55 kg | 121 lbs incl. packaging |
|
Material |
Aluminium, stainless steel, PVC |
|
Supply Voltage |
230 V 50 - 60 Hz |
|
Operating voltage |
19 V DC min. 3.3 A |
|
Input Power |
max. 200 Watts |
|
Appropriate individual diameter |
0.05 - 0.3 mm 0.002 - 0.011 Inch |
|
Max. thread cross section |
20 mm² |
|
Minimum bend radius |
> 10 mm / > 0.39 Inch |
|
Appropriate materials |
Metal wire; plastic; natural, glass and carbon fibres |
More Product Information
- Very robust device for quick and efficient cutting of flat cables
- Exact adjustment of the sample thickness (depending on material)
- Thin, evenly and parallel cut samples with a smooth surface (especially the very small and many cores require a very thin cut to avoid shadows)
- Precise and repeatable measuring results due to reproducible samples
- Large switching capacity in a small footprint
- Switch up to 16 A current - highest in its class
- High breakdown voltage (1,000 V rms between open contacts)
- Ideal for applications such as high current/high power switching, AC line power switching, driving relays for industrial machinery, solenoid switching, and automotive engine control
- Fail-safe interrupt inputs that can detect a fault condition automatically open up relays to their default state
- Compliant with IEC 61000-4-5 Ed.3 standard:ECE R10 is regulated at Ed.2, possible to switch to Ed.2
- AC500V/200A DC600V/200A built-in coupling decoupling network.
- Built-in EV relay welding protection diode in DC line. You can evaluate the lightning surge resistance when charging EV / PHV vehicles, which is required by ECE R10-04 / 05. (EV Fast Charging applicable)
- Maximum output voltage 15kV: In the reliability evaluation test of the lightning surge test, the evaluation including the destructive test can be performed.
- Adopt a large LCD screen operation panel: A large LCD panel screen has been adopted for the operation unit to improve visibility and operability.
- Employs MPU control that simplifies continuous testing: Surge output / waveform switching / polarity switching / sequence operation can be performed automatically.
- Equipped with manual and program modes. Manual mode for standard tests and single condition tests, and Program mode for continuous tests under different conditions. You can easily set test conditions according to your application.
- Excellent safety functions including interlock
- Equipped with waveform check terminal as standard
- You can check the output waveform with your oscilloscope and BNC cable.
- Isolation transformer required to protect the power supply for EUT is available. (option)
- Possible to switch the constant of the decoupling circuit in order to prevent resonance with the power supply.
- Possible to switch to a circuit not including 18uF in the surge output of IEC61000-4-5 Edition 2.0 2005 version).
* This product is a custom product. Please contact us for details.
Customization up to DC1000V is available.
- Device is according to the standard IEC 60811 -501, -507 (heat elongation test, tensile test)
- The samples are taken from the inner side of the sheath and isolator
- All grooves and/or conductive layers are removed
- Developed to slice samples according to IEC 60811 with a thickness between 0.8 and 2.0 mm (0.04” – 0.08”)
- S-parameters DC to 40 GHz, single-ended and mixed-mode
- Impedance Profile with <1 mm resolution, differential and common mode
- Built-in automatic calibration, no manual setup required
- TDR-powered impedance profiling enables precise de-embedding
- Advanced de-embedding including Time Gating and 2Xthru
- Emulate eye diagrams with equalization and advanced jitter analysis
- Complete NRZ and PAM analysis suite for high-speed serial data
- All-in-one solution for testing, compliance, and diagnostics.
- Easy to Use
- No need to break the circuit or insert a shunt
- Small form factors for use on crowded boards
- Variety of Applications
- Bandwidths up to 100 MHz
- Peak currents up to 700 A
- Sensitivities down to 1mA/div
- High Precision Measurements
- Low frequency accuracy of 1%
- Integrated autozero capability
- Fully Integrated with Teledyne LeCroy Oscilloscope
- No additonal hardware is required
- Power is supplied from oscilloscope ProBus connection
- Automatic display of waveforms in Amps and calculated power traces scaled correctly in Watts
- Degauss and Autozero directly from oscilloscope user interface
- DCS025 Deskew Calibration Source
- Provides ability to precisely deskew most voltage probes along with 30, 150 and 500A current probes
-
Ease of use – Less experienced operators can perform an RF calibration up to 500 GHz by simply pushing a button. This reduces the need of experienced users full time on each system.
-
Reduced Soak Time – The system will automatically re-align the probes to the pads if they drift from alignment. This reduces test time and increases throughput.
-
Unattended Use – Measurements can be left running over night or the weekend, testing all devices on the wafer, and at different temperatures without the need of an operator.
-
Calibration Monitor and Re-calibration – System will continuously monitor calibration drift, and automatically re-calibrate the system should the drift exceed a predefined limit.
- Low Noise
- Excellent line/load regulation
- Remote sense
- Coarse and fine voltage controls
- Constant voltage or constant current operation with automatic crossover and mode indication
- Individual On/Off switch per output (not including fixed output)
- Variable ( 1.5V to 5V ) Auxiliary Output
- Shrouded socket-compatible with bare wire and shrouded safety plug connections up to 4 mm
- Simplifies the cable sample arrangement for measuring under a microspcope or the VCPLab
- Perfect for e.g. measuring the indentation of the heat pressure test according to IEC 60811-508
- Arranging with friction wheels, cogwheels and a durable rubber tooth belt
- Easy and quick operation
- Robust device made of aluminium, stainless steel and brass - no corrosion
- Quick sample fixing of a cable sample due to a lever mechanism
VisioCablePro
VisioCablePro® is a brand of iiM GmbH - by Exaktera.
VisioCablePro® - Cable measurement engineering has especially been developed to carry out geometrical measurements, which specifically fulfill cable producers requirements to measure the geometrical features of insulating skins and cable sheaths.
Contact Details
iiM GmbH - VisioCablePro
Neuer Friedberg 5, 98527 Suhl, Germany
Phone: +49 3681 / 455 19-0