Dualos - Fittings - NEO 605B Series
NEO X05 5080 PSI Adapters
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
D |
|
NEO 605B-P-04 |
4, 12 |
JIC-37 Degree |
4 |
0.4375-28 UNJEF Class 3B |
1.67 |
0.40 |
1.45 |
|
NEO 605B-P-06 |
6, 12 |
JIC-37 Degree |
6 |
0.5625-24 UNJEF Class 3B |
1.77 |
0.49 |
1.45 |
| NEO 605B-P-08 |
8, 12 |
JIC-37 Degree |
8 |
0.7500-20 UNJEF Class 3B |
1.89 |
0.56 |
1.45 |
|
NEO 605B-P-10 |
10, 12 |
JIC-37 Degree |
10 |
0.8750-20 UNJEF Class 3B |
1.97 |
0.66 |
1.66 |
| NEO 605B-P-12 |
12 |
JIC-37 Degree |
12 |
1.0625-18 UNJEF Class 3B |
2.04 |
0.69 |
1.66 |
|
NEO 605B-P-16 |
12 |
JIC-37 Degree |
16 |
1.3125-16 UNJ Class 3B |
2.32 |
0.79 |
1.92 |
|
NEO 605B-P-20 |
12 |
JIC-37 Degree |
20 |
1.6250-16 UNJ Class 3B |
- |
- |
- |
*Approximate Dimensions [inches]
Document
More Product Information
-
On-Off power switch
-
20 A Circuit Breaker
-
Outlets – (2) Universal
Test Tap:
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
-
15’ Flexible Power Cord
-
IEC C13 / C14 Connectors
Test Tap:
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
- 600 MHz of instantaneous bandwidth per channel
- Timing synchronization up to 16 channels
- Link Emulation including:
- Phase continuous delay, Doppler, and attenuation changes
- AWGN and Eb/No
- 12 tap (path) multipath fading with Rayleigh, Rician & CW. Angle of Arrival (AOA), k-factor, and correlation controls
- RF frequency agile up/down converters
- Payload Emulation including:
- IMUX/OMUX amplitude and group delay distortion
- Amplifier Compression (AM/AM and AM/PM)
- Phase Noise
- Static and dynamic link emulation
- Ephemeris data generation using SATGEN
- Remote instrument control through ACEClient application
EMI Measurements:
- FFT-based dual-channel receiver
- According to CISPR16-1-1
- Peak, Quasi-Peak, and Average Detectors
- Resolution Bandwidth Filters of 200 Hz, 9 kHz, and 120 kHz (CISPR), and 1 kHz and 10 kHz (MIL)
- The fastest receiver in the market: Line and Neutral measurements with the 3 detectors simultaneously (6 simultaneous measurements)
-
On-Off power switch
-
30 A Circuit Breaker
-
Inlet - NEMA L6-30
-
Outlets – NEMA L6-30R
Test Tap:
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
Dualos
Website
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors