Dualos - Fittings - NEO 805C Series
NEO X05 5080 PSI Adapters
|
Part Number |
Port Size 1 |
Thread End [1] |
Port Size 2 |
Thread End [2] |
A |
B |
D |
|
NEO 805C-P-04 |
4, 12 |
JIC-37 Degree |
4 |
0.4375-28 UNJEF Class 3A |
1.78 |
- |
1.88 |
|
NEO 805C-P-06 |
6, 12 |
JIC-37 Degree |
6 |
0.5625-24 UNJEF Class 3A |
1.81 |
- |
1.88 |
| NEO 805C-P-08 |
8, 12 |
JIC-37 Degree |
8 |
0.7500-20 UNJEF Class 3A |
1.88 |
- |
1.88 |
|
NEO 805C-P-10 |
10, 12 |
JIC-37 Degree |
10 |
0.8750-20 UNJEF Class 3A |
2.03 |
- |
2.31 |
| NEO 805C-P-12 |
12 |
JIC-37 Degree |
12 |
1.0625-18 UNJEF Class 3A |
2.10 |
- |
2.25 |
|
NEO 805C-P-16 |
12 |
JIC-37 Degree |
16 |
1.3125-16 UNJ Class 3A |
2.15 |
- |
2.50 |
|
NEO 805C-P-20 |
12 |
JIC-37 Degree |
20 |
1.6250-16 UNJ Class 3A |
2.14 |
- |
2.70 |
*Approximate Dimensions [inches]
More Product Information
- Robust case seals against extraneous light
- Central control unit
- Semi-automatic focussing and illumination
- Safe from impacts and vibrations
- Quasi shadow free transmitted light
- Optimal system status for lighting, optics and camera
- A measurement with 2 cameras is possible
- Adjustable operation distance for 2D measurements in laboratories
- Very precise measurement due to high resolution sensors
- Standardised individual components
- Very easy measuring procedure
- Suitable software VELOX and CAQ-System ProCable available
-
15’ Flexible Power Cord
-
IEC C13 / C14 Connectors
-
3ft.
-
(2) fork terminals (current)
-
(1) fork terminals (ground)
-
(2) Shielded Banana (voltage)
- Device and operation are according to the standard IEC 60811-506 (IEC 60811-1-4) point 8.5
- Case set offers all required weights for the test
- Easy operation
- Very robust and solid construction
- Steel impact piece included
- Up to 3 Samples can be tested simultaneously
- Device suitable for positioning in a cold chamber - Product No.: 402.0020.02
- 600 MHz of instantaneous bandwidth per channel
- Timing synchronization up to 16 channels
- Link Emulation including:
- Phase continuous delay, Doppler, and attenuation changes
- AWGN and Eb/No
- 12 tap (path) multipath fading with Rayleigh, Rician & CW. Angle of Arrival (AOA), k-factor, and correlation controls
- RF frequency agile up/down converters
- Payload Emulation including:
- IMUX/OMUX amplitude and group delay distortion
- Amplifier Compression (AM/AM and AM/PM)
- Phase Noise
- Static and dynamic link emulation
- Ephemeris data generation using SATGEN
- Remote instrument control through ACEClient application
- Single or dual-channel display
- Agilent HP 437 & Agilent HP 438, and Boonton 4220A & 4230A emulation
- Automatically loads sensor data
- Simple software control via SCPI language
- IEEE-488 and RS-232 interfaces standard
The 4240 series of CW RF power meters provides the high speed measurement capability needed in a production environment, as well as the simplicity of operation required for bench top use. It provides very accurate measurements from -70 dBm to +44 dBm (sensor dependent) and has a rapid display update rate for tuning applications. The easy to read LCD displays both channels simultaneously with numeric and bar graph information.
- NEO 941 parts are AS5836 compatible (Clam Shell Clamps not Included)
- NEO 942 parts are AS1653 compatible (Clam Shell Clamps not Included)
Dualos
787 SMOT compliant caps and plugs for hydraulic, fuel or DI water lines. 3000 PSI & 5000 PSI fine and extra fine threaded aircraft to JIC adaptors