Teledyne LeCroy - PPE6KV 1000:1 400 MHz 50M Ohm High-Voltage Probe

Teledyne LeCroy - PPE6KV 1000:1 400 MHz 50M Ohm High-Voltage Probe

The PPE series of probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are five fixed-attenuation probes covering a range from 2 kV to 20 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV.

New technology which utilizes hybrid circuitry (and switch reading for probes with switchable gain/attenuation) minimizes ringing and overshoot to provide a precise response.

All fixed-attenuation, standard probes automatically re-scale any Teledyne LeCroy 9300C or LC series oscilloscope for the appropriate attenuation factor of the probe.

More Product Information

Teledyne LeCroy - PPE5KV 100:1 400 MHz 50M Ohm High-Voltage Probe

The PPE series of probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are five fixed-attenuation probes covering a range from 2 kV to 20 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV.

New technology which utilizes hybrid circuitry (and switch reading for probes with switchable gain/attenuation) minimizes ringing and overshoot to provide a precise response.

All fixed-attenuation, standard probes automatically re-scale any Teledyne LeCroy 9300C or LC series oscilloscope for the appropriate attenuation factor of the probe.

Teledyne LeCroy - PPE4KV 100:1 400 MHz 50M Ohm High-Voltage Probe

The PPE series of probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are five fixed-attenuation probes covering a range from 2 kV to 20 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV.

New technology which utilizes hybrid circuitry (and switch reading for probes with switchable gain/attenuation) minimizes ringing and overshoot to provide a precise response.

All fixed-attenuation, standard probes automatically re-scale any Teledyne LeCroy 9300C or LC series oscilloscope for the appropriate attenuation factor of the probe.

Teledyne LeCroy - PPE2KV 100:1 400 MHz 50M Ohm High Voltage Probe

The PPE series of probes are suitable for a wide range of applications where high-voltage measurements must be made safely and accurately. There are five fixed-attenuation probes covering a range from 2 kV to 20 kV, and one switchable probe providing ÷10/÷100 attenuation for voltage inputs up to 1.2 kV.

New technology which utilizes hybrid circuitry (and switch reading for probes with switchable gain/attenuation) minimizes ringing and overshoot to provide a precise response.

Teledyne LeCroy - HVP120 400 MHz High Voltage Passive Probe
  • 400 MHz probe bandwidth
  • 900 ps rise time
  • 1000 Vrms maximum input
  • Up to 6 kV transient overvoltage

Teledyne LeCroy - HVD3605 6kV, 100 MHz High Voltage Differential Probe
  • 6 kV CAT safety rated
  • Widest differential voltage range available
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC or DC coupling
  • 6 meter cable
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities
  • Wide oscilloscope compatibility

Teledyne LeCroy - HVD3206 2kV, 120 MHz High Voltage Differential Probe
  • 2 kV CAT safety rated
  • Only 1500 Vdc safety rated probe per IEC/EN 61010-031:2015
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC or DC coupling
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities
  • Wide oscilloscope compatibility

Teledyne LeCroy - HVD3106 1kV, 120 MHz High Voltage Differential Probe
  • 1 kV CAT safety rated
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC or DC coupling
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities
  • Wide oscilloscope compatibility
Teledyne LeCroy - HVD3102 1kV, 25 MHz High Voltage Differential Probe
  • 1 kV CAT safety rated
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC or DC coupling
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities
  • Wide oscilloscope compatibility

Teledyne LeCroy - HVD3206-6M 2kV, 80 MHz High Voltage Differential Probe with 6m cable
  • 2 kV CAT safety rated
  • Only 1500 Vdc safety rated probe per IEC/EN 61010-031:2015
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC or DC coupling
  • 6 meter cable
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities
  • Wide oscilloscope compatibility