Products

Displaying 625 - 636 of 754
Global shutter and rolling shutter CMOS sensors available  USB3 Vision  High sensitivity with both front and back illuminated sensors (BSI)  Side mounted USB connectors for ease of use in OEM solutions  High sensitivity with pixel sizes from 2 µm to 3.45 µm  Windows operating system and Linux SDKs (for embedded vision systems)  3-Year Warranty
High speed 120 kHz, high resolution 28 μm or 900 dpi  No missing or interpolated pixels  Exposure control  Mono/HDR mode  Precalibrated pixel size for metrology applications  Camera Link HS fibre interface
Image acquisition from Camera Link Base camera  Supports Camera Link® operations up to 85MHz  Supports 32/64-bit Windows platforms  Quarter-length PCI Express x1 Board  Power Over Camera Link® (PoCL) Compliant  Offers external acquisition control signals on single PCIe x1 slotROHS compliant
Supports PCI Express Rev 2.0 x4 or higher, backwards compatible with PCIe Rev 1.10 slots  Up to 512MB of high-speed image memory  Single slot solution with reconfigurable camera control and general purpose input/outputs
Long cable lengths at maximum image acquisition rates  Data forwarding rate for distributed image processing  Fully supported by Sapera Vision Software SDKs
Up to 4 GHz Bandwidth  ±60 V Offset Capability  ±800 mV Dynamic Range  50 kΩ DC Input Impedance  1.2x Attenuation for low additive noise  MCX terminated cable with wide variety of connections:  Solder-in (4 GHz)  Coaxial Cable to U.FL receptacle (3 GHz)  MCX PCB Mount (4 GHz)  Browser (500 MHz)  ProBus Interface
Fully Integrated: With the ProBus™ interface, the AP033 becomes an integral part of the oscilloscope. The probe sensitivity and offset can be controlled from the oscilloscope front panel, the probe front panel, or by using remote control commands (GPIB or RS-232). Sensitivity, offset, input capacitance, and common mode voltage range are displayed on the oscilloscope screen. When used with a LeCroy digital oscilloscope, no external power supply is required.
Easy to Use No need to break the circuit or insert a shunt Small form factors for use on crowded boards Variety of Applications
Differential active probes are like two probes in one. Instead of measuring a test point in relation to a ground point (like single-ended active probes), differential probes measure the difference in voltage of a test point in relation to another test point
Highest resolution - 12 bits all the time  Bigger Display, smaller footprint, most bench space  More capability, increased productivity
High voltage differential probes provide high CMRR over a broad frequency range to simplify the measurement challenges found in noisy, high common-mode power electronics environments. The probe’s design is easy-to-use and enables safe, precise high voltage floating measurements.
The PPE6KV-A and HVP120 can handle up to 6000 Vpeak transient overvoltages and are designed for probing up to 2000 Vrms and 1000 Vrms respectively. Fast rise times, excellent frequency response, and a variety of standard accessories make these probes safe and ideal for high voltage measurement applications